Problem:

The above error occurred when installing the WinSpool/400 95/NT software.

Solution:

You may have a version of the Visual Basic 5.0 Runtime DLL (MSVBVM50.DLL Version: 5.00.3724) in the WINDOWS\SYSTEM directory which was older than the one shipped with WinSpool/400 95/NT, but the file date was newer, so the WinSpool/400 installation process didn't install the newer version as expected. The TABCTL32.OCX and COMDLG32.OCX files were also older versions 5.00.3714.

You should rename the files listed above and then reinstall the Visual Basic 5.0 runtime files and the WinSpool/400 95/NTsoftware. The software appears to work just fine now.