Unmonitored Error 3315 with WinSpool/400 Batch Report Server - Support

Unmonitored Error 3315 with WinSpool/400 Batch Report Server

From Support

Jump to: navigation, search
If you have a question or seek clarification, please call Technical Support.

Problem:

User would start the Batch Report Server and get the following error in the log file:

INFO: Spool File SS671R1 Job: (053545/EPBBCH/SS671P/#4) download to PC File C:\WSPBCH32\REPORT.TXT was successful. 20/1/2003, 08:35:05 Trace point: 3700 INFO: Spool File SS671R1 Job: (053545/EPBBCH/SS671P/#4) copy to PC File D:\E\SS671R10000005.TXT was successful. 20/1/2003, 08:35:05 Trace point: 4500 ERROR: An unmonitored error occurred while processing spool files. The next message should describe the error. 20/1/2003, 08:35:05 Trace point: 7500 ERROR: ERROR: Unmonitored error 3315 Field 'AS/400 Report Archive Catalog Table.Spool_FormType' can't be a zero-length string. Trace point: 7500 20/1/2003, 08:35:05 Trace point: 7500


Download Pass Completed 20/1/2003 08:35:05 ------

Solution:

The Form Type in the spool file was blank. Have the user verify that the Form Type of the spool file contains a value and run it again.